In short, it gives you infinite capabilities to solve all your analytical challenges in lc and lcms. View online or download agilent technologies 1260 infinity ii user manual, manual, installation manual. Agilent 1260 infinity binary pump user manual agilent technologies notices agilent technologies, inc, no part of this manual may be reproduced in any form. Agilent infinitylab lc series 1260 infinity ii binary pump. Agilent 1260 infinity quaternary pump vl user manual pdf. Gradient formation is based on highpressure mixing and delay volumes standard or low can be easily configured by. This manual covers the agilent 1260 infinity binary pump g12b. For instructions on how to change between the two configurations, see the. Binary gradients are created by highpressure mixing. Agilent 1260 infinity binary pump user manual crawford scientific. Degassing is not included but a vacuum degasser is available as a separate product for.
Compatible with conventional and ultrahigh performance lc with an operating pressure of up to 600 bar, the 1260 infinity ii quaternary pump and the 1260 infinity binary pump are a perfect match for our poroshell 120 columns. Agilent 1260 infinity quaternary lc manual and quick reference. Metering of solvent and delivery to the highpressure side are. While these parts are as good from a performance perspective, they are no longer used for 1260 infinity. We have 14 agilent technologies 1260 infinity manuals available for free pdf download.
Binary pump uhplc, 1260 infinity ii binary pump agilent. Hplc maintenance replacing the pump seals on an agilent 11001200 1260 hplc pump. Page 19 the stroke volume for the pump is by default set to auto mode. The 1260 infinity ii binary pump is ideally suited for a broad range of lc applications using columns with conventional particles, superficially porous particles, or sub2micron stm particles.
User manual, quick start manual, operators quick manual. Hplc maintenance removing the pump head on an agilent 11001200 1260 hplc pump duration. Agilent 1260 infinity binary pump user manual the highspeed proportioning valve and preconfigured vacuum degasser of the 1100 binary pump allows convenient lowpressure mixing of up to four solvents and the highest flexibility in solvent choices. The precision of retention times of the 1260 infinity ii flexible pump was evaluated under demanding conditions and compared to the 1260 infinity ii binary pump.
Caution agilent 1260 infinity pump heads have been discontinued for agilent 1260 infinity binary pumps a number of 1260 infinity binary pumps have been shipped with pump heads labeled as 1260 infinity pump heads and passive inlet valves. Agilent infinitylab analytical lc solutions 1220, 1260. This binary pump can be remotely controlled via chemstation software or by an external. Download agilent 1260 infinity quaternary pump vl user manual book pdf free download link or read online here in pdf. The agilent 1260 infinity quaternary pump now comes with an extended pressure range of up to 600 bar. Interact with agilent products as if they were real. Hplc maintenance reinstalling a pump head on an agilent 1100. Agilent 1260 infinity series g11b quat pump with built in an agilent 1260 infinity ii lc for the analysis of paracetamol and its impurities, and proves pump g11b. To speak with a representative, please fill out the contact form below or call us directly. Agilent 1260 infinity isocratic pump and quaternary pump. The agilent 1260 infinity binary pump and 1260 infinity standard autosampler have been carefully modified for superior sfc performance. Asslam o alaikum may peace and mercy be on all of you if i use isocratic elution on quarternay pump agilent 1260 infinity series, the pressure is different from that pressure when i use binary pump to elute same composition as i did in isocratic elution, the question is that why pressure is different while composition of the mobile phase is same. This allows the usage of smaller particle size columns. Review on hplc agilent 1260 series, degasser, auto sampler, quaternary pump and column compartment.
Agilent 1290 infinity binary pump user manual agilent technologies 1 introduction features 10 overview of the binary pump 11 pump principle 12 system overview 15 leak and waste handling 15 this chapter gives an introduction to the pump, instrument overview and internal connectors. The agilent 1260 infinity binary pump is designed for applications with rrht 1. In addition it is also ideally suited for standard hplc using 4. Replacing the jet weaver on an agilent 1290 g4220x binary pump. The 1260 infinity ii lc system is a robust hplc that offers the widest choice of modules for analytical hplc and entrylevel uhplc, delivering the performance, reliability, and robustness you need for highest confidence in your daily results. Agilent infinitylab lc series 1290 infinity ii high speed. Agilent technologies 1260 infinity manuals manuals and user guides for agilent technologies 1260 infinity. Agilent 1290infinity binary pump agilent 1290infinity quaternary pump programmedgradient 10 15 20 25 30 0 5 10 15 20 25 6 agilent 1290 infinity lc with iset iset for infinitely better method transfer iset intelligent system emulation technology makes the agilent 1290 infinity lc the most adaptive uhplc system available. Explore a new level of detail for your preferred solution. Agilent 1260 infinity ii series g4782a sfc binary pump conquer. Review on hplc agilent 1260 series, degasser, auto sampler. Specification compendium 9 pumps 1 agilent 1290 infinity ii high speed pump g7120a agilent 1290 infinity ii high speed pump g7120a physical specifications table 3 physical specifications type specification comments weight 21. Read online agilent 1260 infinity quaternary pump vl user manual book pdf free download link book now. Agilent technologies 1260 infinity user manual pdf.
Help with agilent 1290 binary pump error chromatography. Use, duplication or dis closure of software is subject to agilent technologies standard commercial license terms, and nondod departments and agencies of the u. Agilent technologies 1260 infinity ii user manual pdf. Government will 1260 infinity binary pump user manual. The sfc version of the pump performs precise metering up to flow rates of 5 mlmin. It provides gradient generation byhighpressure mixing.
Agilent technologies 1260 infinity ii water pump operation. This manual covers the agilent infinitylab lc series 1260 infinity ii binary pump g7112b. The new 1260 infinity lc sets higher standards in performance and value to give you more confidence in your results. Agilent 1290 infinity ii flexible pump user manual agilent technologies 1 introduction product description 10 features 11 operating principle 12 positions of the multi purpose valve 14 leak and waste handling 19 waste concept 21 this chapter gives an introduction to the module, instrument overview and internal connectors. A degassing unit is included for applications that require best flow. My service engineer has not yet opened the pump as he performed a pm on this unit in late november last year but he has spoken to guys at agilent about our problem and they said that with this type of error, the pump drive electronics is most probably the reason for failure and since the drive encoder is not a serviceable part he sees no.
The agilent 1260 replaced the agilent 1200 and delivers results faster to save time and money. Infinitylab lc series 1260 infinity ii binary pump user manual 11 introduction 1 instrument and operation principle of operation the binary pump is based on a twochannel, dualpiston inseries design which comprises all essential functions that a solvent delivery system has to fulfill. Analytical and semipreparative purifications the wide flow range of the 1260 infinity ii quaternary pump up to 10 mlmin perfectly supports standard and semipreparative applications. Agilent 1290 infinity binary pump user manual 11 introduction 1 overview of the binary pump overview of the binary pump the agilent 1290 infinity binary pump comprises two identical pumps integrated into one housing. The quaternary pump generates gradients by low pressure mixing from four. Agilent 1290 infinity binary and quaternary lcs with. These parts can be accessed from the front simple repairs and dont require to remove the pump from the system. Agilent 1260 infinity lc infinitely more confident. Agilent 1260 series infinity hplc stack hplc system. Hplc maintenance tutorial on how to remove the pump head on an 11001200 1260 agilent hplc. This manual covers the agilent 1260 infinity quaternary pump vl g11c. Agilent 1260 infinity ii sfc binary pump infinity lab lc series user manual mb. Agilent 1260 infinity isocratic pump and quaternary pump user.
The agilent 1260 infinity ii binary pump features a multi point compressibility calibration. Agilent technologies 1260 infinity ii pdf user manuals. Agilent technologies 1260 infinity user manual pdf download. Hplc maintenance replacing the high pressure filter on an agilent 1290 g4220x or g4204x pump. Page 1 agilent 1260 infinity binary pump user manual agilent technologies page 2 1987 or any equivalent agency regulation or contract clause. Agilent 1290 infinity ii lc specification compendium. The compressibility of a solvent is determined at different pressures from 0. Agilent s virtual information system get new and deeper insights into the agilent product and solution portfolio. While these parts are as good from a performance perspective, they are no longer used for 1260 infinity binary. The 1260 infinity ii binary pump is ideally suited for a broad range of uhplc applications using columns with conventional, superficially porous or sub2micron particles. Hplc maintenance replacing the high pressure filter on. Tt326 changes on page 3839, add part 14003166 ring stand, mounting bracket. Fast and precise gradients the 1260 infinity ii binary pump is the perfect choice for fast and precise gradients using lcms, as well as uvonly systems.
Agilent 1260 infinity binary pump for standard hplc and rapid resolution lc the agilent 1260 infinity binary pump is designed for applications with rrht 1. Agilent 1260 infinity ii auto injector hplc work duration. Hplc maintenance removing the pump head on an agilent. The 1260 infinity ii binary pump uses highpressure mixing for uhplc gradient formation and solvent blending from one or two solvents at pressures up to 600 bar and flow rates up to 5 mlmin. We are not their representatives nor authorized resellers. Hplc instrumentation 17 binary pump solvent mixing. Agilent 1260 infinity binary pump pdf free download. Hplc maintenance replacing the pump seals on an agilent. The 600 bar power range combines with 80 hz uv detector speeds and up to 10 times higher. This pump delivers reproducible gradients for routine hplc or uhplc applications with uv or ms detection where speed, resolution, and uncompromised data quality are essential.
Analytical hplc, 1260 infinity ii lc system agilent. In addition, the composition accuracy, delay volume, and flow accuracy of both pumps were also evaluated by running step gradients. The 1290 infinity lc is the first system that provides the foundation for method transfer to or from any agilent or non agilent uhplc or hplc system. G11b agilent 1260 agilent 1260 infinity series g11b quat pump with built in degasser. Infinitely better analytical sfc solutions agilent 1260. View and download agilent technologies 1260 infinity g15c user manual online. Configure your favorite agilent system in a virtual 3d environment. The capillary pump is based on the 1200 series binary pump pressure limit.
434 1446 1418 408 229 767 375 230 1373 1105 1074 1415 916 1552 472 633 1361 697 884 1 717 1422 569 623 457 854 465 1294 1107 1393